• 首页 | 期刊简介 | 编委会 | 投稿须知 | 出版道德规范 | 下载专区 | English
陈志杰,李钊,刘义捷,刘海*,齐橼.基于超声相控阵和逆时偏移成像的套筒灌浆饱满度无损检测方法[J].实验力学,2022,37(5):657~668
基于超声相控阵和逆时偏移成像的套筒灌浆饱满度无损检测方法
Imaging-based inspection of grouted splice sleeves by reverse-time migration using an ultrasonic phased array
投稿时间:2021-09-23  修订日期:2021-10-28
DOI:10.7520/1001-4888-21-227
中文关键词:  装配式结构  灌浆套筒  无损检测  超声成像  逆时偏移
英文关键词:precast concrete structure  grouted splice sleeve  non-destructive testing (NDT)  ultrasonic imaging  reverse time migration
基金项目:广东省基础与应用基础研究基金项目(2019A1515011162, 2021A1515010881)
作者单位
陈志杰 广州大学 土木工程学院, 广东广州 510006 
李钊 济南轨道交通集团有限公司, 山东济南 250014 
刘义捷 广州大学 土木工程学院, 广东广州 510006 
刘海* 广州大学 土木工程学院, 广东广州 510006 
齐橼 1.广州大学 土木工程学院, 广东广州 510006
2.广州市妇女儿童医疗中心国家儿童区域医疗中心(中南), 广东广州 510620 
摘要点击次数: 527
全文下载次数: 73
中文摘要:
      灌浆套筒连接是装配式建筑最主要的连接方式之一,套筒的灌浆饱满度决定了装配式建筑的稳定性和抗震性。本文提出一种基于逆时偏移(RTM)成像算法的相控阵超声检测方法,可对装配式套筒连接处可能存在的灌浆缺陷进行检测,本文通过数值仿真试验和室内模型试验对所提方法的有效性进行了验证,其中数值仿真结果表明:RTM算法与传统超声全聚焦(TFM)算法相比,具有更高的成像精度和清晰度,能准确识别套筒内部的空洞、不密实等灌浆缺陷。室内试验结果表明:在RTM重构图像中,与灌浆密实套筒相比,灌浆不密实套筒的反射信号会低9dB,此特征可以识别注浆缺陷。研究结果表明本文提出的相控阵超声成像方法适用于预制结构的套筒灌浆缺陷检测。
英文摘要:
      Grouted sleeve has become one of the most important methods for connecting the prefabricated construction (PC) components. The compactness of the grouted sleeves plays a critical role in the structural safety and earthquake resistance for prefabricated construction. In this paper, an ultrasonic imaging method is proposed for the inspection of the compactness of grouted splice sleeves in PC structures by reverse time migration (RTM) using a phased array. Numerical and laboratory experiments are carried out to assess the feasibility of the proposed method. Numerical results show that the proposed RTM method can reconstruct images of the buried sleeves with a higher resolution and a greatly-improved accuracy, compared with the total focusing method (TFM). In the laboratory experiment, the insufficiently-grouted sleeve has a reflection, which is about 9 dB stronger than the fully-grouted one. The proposed ultrasonic imaging method has a great potential for inspecting the grouting quality of splice sleeves in PC constructions in the near future.