肖琦,王德弘*,徐晶.输电线路挤扩支盘桩受力特性的试验研究[J].实验力学,2015,30(1):124~130 |
输电线路挤扩支盘桩受力特性的试验研究 |
Experimental Study of Squeezed Branch Pile Mechanical Characteristics in Transmission Line Engineering |
投稿时间:2014-01-07 修订日期:2014-08-18 |
DOI:10.7520/1001-4888-14-010 |
中文关键词: 输电线路 杆塔基础 挤扩支盘桩 受力特性 静载试验 |
英文关键词:transmission line tower foundation squeezed branch pile mechanical characteristics static loading experiment |
基金项目:国家自然科学基金(51378095)资助,吉林省科技发展计划项目(201105061)资助 |
|
摘要点击次数: 1788 |
全文下载次数: 741 |
中文摘要: |
挤扩支盘桩是一种具有较高的承载力和较小的沉降变形的新桩型。对某220kV送电线路工程的挤扩支盘灌注桩分别开展了下压+水平联合工况、上拔+水平联合工况和水平荷载的现场真型静载荷试验,得到了挤扩支盘桩在不同工况下的承载力、桩身轴力、桩周侧阻力和桩端阻力的分布规律。支盘桩的抗拔承载力较普通灌注桩提高约20%,支盘的存在使得桩身轴力呈现明显的阶跃式变化。根据挤扩支盘桩的荷载传递规律,建议承力盘间距不小于桩身设计直径的4倍,且不小于承力盘设计直径的2倍。 |
英文摘要: |
Squeezed branch pile is a new type of pile, which has higher carrying capacity and smaller settlement deformation. On-site static loading experiments of true squeezed branch piles taken from a 220KV transmission line engineering were carried out respectively, under different load conditions including compression plus horizontal combined loading, uplift plus horizontal combined loading and horizontal loading alone conditions. The bearing capacity, axial stress, and distribution of pile side friction and pile tip resistance of squeezed branch pile under different conditions were obtained. The uplift capacity of squeezed branch pile increases by about 20 percent relative to normal piles. The axial stress of squeezed branch pile presents obvious step jumping variation due to the branch plate. According to the load transfer mechanism of single squeezed branch pile, the space between load-bearing plates should be not less than 4d and 2D. |
查看全文 下载PDF阅读器 |
关闭 |